BOSTER - SAFETY SWITCH WITH MAGNETIC HOLD 4 KGS
Position control for doors / casings on dangerous machinery with magnetic holding devices
40N integrated stainless steel magnetic door holding
Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
Level of performance without an external controller: PL = d
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3
Safety Integrity Level: SIL 2
Cycle before dangerous failure: B10d = 2,000,000 at 2A
Max. activation distance: 4 mm, 2 mm hysteresis
Holding Force: transmitter + receiver in contact = 40N
Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code
Reset: automatic
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 1
Material: INOX 316L mirror polished
Electrical connection: 3, 6, 12m cable
Water resistance: IP 67
Temperature: -25ÃÂðC to +60ÃÂðC
Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability
Certification: TÃÂÃÂV Rheinland 01/205/5238/12