SSR - SAFETY SWITCH STAND ALONE - CAT.1
Position control for doors / casings on hazardous machinery
Contactless encoded electronic sensor with relay
Up to 8 zone differentiation codes
Safety contacts 2A / 250V
Level of performance without an external controller: PL = c
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 1
Cycle before dangerous failure: B10d = 2,000,000 at 2A
Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US:
8 mm, 2 mm hysteresis
Max. activation distance 2SSR24V/2SSR24BX:
4 mm, 2 mm hysteresis
Safety contacts/diagnostics 3SSR24V : 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary
Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US : 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V)
Security contacts 2SSR24V: 2 x NO 2A/250V
Security contacts 2SSR24BX : 1 x NO 2A/250V and 1 x NF 2A/250V
Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code
Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes
Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX : Red LED indicating code absence (not transmitter)
Indicator 5SSR24BX-US : Two-color red/green LED
Reset: automatic
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 2 (double wall brackets)
Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US
Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT
Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT
Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation
Temperature: -25ðC to +60ðC
Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability