SPEEDTRONIC N - CONTROLS THE ZERO SPEED OF MOTORS WITH UNLOCK CONTROL
Zero speed control with lock release
Door unlocking control on motor shutdown
Detection of asynchronous motors stoppage without external sensor
Removable terminals
Performance level with AWAX controller: PL = e
Safety category: 4
Time before dangerous failure: MTTFd = 100 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: approx. 2 to 7s adjustable at front
Persistence: approx. 20 mV to 700 mV adjustable front
Motor power: up to 3x690 VAC
Protection for severed wires: yes
Protection against disconnection of motor coiling: yes
Safety contacts: 3x NO 8A/250V redundant
Diagnostics: 1x NF 8A/250V redundant parallel.
1 PNP "OK" output indicating motor coiling presence.
1 PNP "ERROR" output indicating a synchronization malfunction.
1 "RS" system reset input.
Indicators: 3 LEDs for diagnostics
Reset: automatic
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 20 electrical box
Electrical connection: Maximum 14 AWG (2.08 mmò) / 250V minimum
Temperature: -20ðC to +60ðC
ISAC ENTERPRISES